pravin3113
@pravin3113
Trusted Member
Joined: Feb 20, 2010
Last seen: Oct 1, 2019
Topics: 0 / Replies: 87
Reply

Have you talked to LS-DYNA tech support? They are pretty good at getting back. If they do not know the answer, I think they will talk to their develop...

5 years ago
Reply

Are you sure you are taking into account a factor of 2 in the definition of engineering shear as used by Abaqus? Also, make sure you are comparing the...

6 years ago
Reply

If abaqus isnt the command, it may be abq6xxx where xxx is the version number. Check your .bat files in the site folder.

10 years ago
Topic
10 years ago
Replies: 2
Views: 376
Reply

Some of my previous posts on this site should address this error. Simply running your job on the command prompt does not invoke VS and Fortran. In the...

10 years ago
Topic
10 years ago
Replies: 4
Views: 581
Reply

I have never seen micromechanical models in which bone or cartilage has been modeled as a poroelastic medium.

10 years ago
Topic
10 years ago
Replies: 1
Views: 443
Reply

afrediens comments are spot on. Here are my 2 cents: You can never fully characterize any material but the hope is by applying a few basic loading ...

11 years ago
Reply

Manually? I am not sure what you mean. You can write a code in USDFLD and, based on a field variable, get rid of elements and the whole process may be...

11 years ago
Reply

Correct@lumpwood. It is model change, add or model change, remove that I had in mind.

11 years ago
Topic
11 years ago
Replies: 6
Views: 591
Reply

Those make me feel a little stupefied here. You are an undergraduate student, you teach at a university, and you teach abaqus. I just hope this is jus...

11 years ago
Reply

If you are working with a CAE, there must be a .jnl (journal) file saved in the scratch directory. Now, do the post-processing only once. Then, open t...

11 years ago
Topic
11 years ago
Replies: 3
Views: 386